AIS31TESTSEL=BEFORE, CONDBYPASS=NORMAL, BYPAIS31=NORMAL, HEALTHTESTSEL=BEFORE, FORCERUN=NORMAL, SOFTRESET=NORMAL, BYPNIST=NORMAL, ENABLE=DISABLED, TESTEN=NOISE
No Description
ENABLE | TRNG Module Enable 0 (DISABLED): Module disabled 1 (ENABLED): Module enabled |
TESTEN | Test Enable 0 (NOISE): Non-determinsitc random number generation 1 (TESTDATA): Pseudo-random number generation |
CONDBYPASS | Conditioning Bypass 0 (NORMAL): The conditionig function is used 1 (BYPASS): The conditioning function is bypassed |
REPCOUNTIEN | IRQ enable for Repetition Count Test |
APT64IEN | IRQ enable for APT64IF |
APT4096IEN | IRQ enable for APT4096IF |
FULLIEN | IRQ enable for FIFO full |
SOFTRESET | Software Reset 0 (NORMAL): Module not in reset 1 (RESET): The continuous test, the conditioning function and the FIFO are reset |
PREIEN | IRQ enable for AIS31 prelim. noise alarm |
ALMIEN | IRQ enable for AIS31 noise alarm |
FORCERUN | Oscillator Force Run 0 (NORMAL): Oscillators will shut down when FIFO is full 1 (RUN): Oscillators will continue to run even after FIFO is full |
BYPNIST | NIST Start-up Test Bypass. 0 (NORMAL): NIST-800-90B startup test is applied. No data will be written to the FIFO until the test passes. 1 (BYPASS): NIST-800-90B startup test is bypassed. |
BYPAIS31 | AIS31 Start-up Test Bypass. 0 (NORMAL): AIS31 startup test is applied. No data will be written to the FIFO until the test passes. 1 (BYPASS): AIS31 startup test is bypassed. |
HEALTHTESTSEL | Health test input select 0 (BEFORE): Before conditioning 1 (AFTER): After conditioning |
AIS31TESTSEL | AIS31 test input select 0 (BEFORE): Before conditioning 1 (AFTER): After conditioning |
NB128BITBLOCKS | Number of 128b blocks in AES-CBCMAC |
FIFOWRSTARTUP | Fifo Write Start Up |